Populating the memory according to the following guidelines resolves this POST error:\015\012\015\012
    \015\012
  • DIMMs must be configured in identical pairs.
  • \015\012
  • The system will not boot properly if multiple DIMMs of varying density or type are installed in the system.
  • \015\012
  • The Entry model servers come with a single 512 MB DIMM. If\015\012additional DIMMs are to be added to the existing 512MB DIMM, then\015\012another 512 MB DIMM has to be added along with the new pair of DIMMs,\015\012or it has to be removed when adding the next pair.
  • \015\012
  • Valid DIMM pair combinations use slots 1/5 (Bank A), slots 2/6 (Bank B), slots 3/7 (Bank C), and slots 4/8 (Bank D).
  • \015\012
  • Up to 16 GB of memory are supported on the Dual-Core 5000, and 5100 series
  • \015\012
  • Up to 32 GB of memory are supported on the Dual-Core 5200 series, Quad-Core 5300, and 5400 series
  • \015\012
  • FBDIMMs must be installed in pairs unless operating in\015\012single-FBDIMM mode. The server supports single-FBDIMM mode only in\015\012FBDIMM slot 1A. FBDIMMs must be installed in sequential order,\015\012beginning with bank A.
Repair Help & Product Troubleshooting for HP Compaq ProLiant ML350 G3 Server

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.

Suggested Questions/Answers :

RAM error - HP Compaq ProLiant ML350 G3 Server


Populating the memory according to the following guidelines resolves this POST error:\015\012\015\012\015\012 DIMMs must be configured in identical pairs. \015\012 The system will not boot pro ... HP Compaq ProLiant ML350 G3 Server

HP Proliant ML370 Server: Led shows red light


Hi there,\015\012Your server definetly has issue booting first of all this is a little old server model so first open and blow air from a blower (&not use vaccum cleaner)since problem could be anything frm a struck cpu fan or anything ... HP Compaq ProLiant ML530 Server

Connect HP Proliant ML350 Server.


Hi,Please verify if your server power specs support 110 or 220 V. If you are in the US, eventhough you might have connected a 220V cable the line voltage can be 110.Check with your power company if they can provide you the necessary ... HP Compaq ProLiant ML350 G3 Server

Compaq ProLiant ML370 G3


Hello,\015\012\015\012How big if your environment? How many users? Do you have remote access needs? If your environment is under 75 users then you might want to consider moving to Windows Small Business Server. It's a great little pack ... HP Compaq ProLiant ML370 G3 Server

Fan flow error 1611 I/O


The\015\012ProLiant DL380 G3 server requires that both primary and redundant fans\015\012exist in a specific configuration in order to perform optimally. Any\015\012deviation from the specified configuration will cause one of the above\015\012error m ... HP Compaq ProLiant DL580 G4 (430811001) Server

Hp proliant ml350 g3 scsi bios not installed - HP Compaq ProLiant ML350 G3 Server


... HP Compaq ProLiant ML350 G3 Server

Wont read memory


The memory might be correct, but the server may require matching RAM. Check your hardware specs for details, but you may need two matching modules in the correct banks for the server to recognize and utilize the RAM. ... HP Compaq ProLiant ML310 Server

Second Led on HDD is flashing Red


You can run "chkdsk /r" coomand to recover your harddisk.Also if you can delete partition and then create new partition thehn format it so all errors are fixed . ... HP Compaq ProLiant DL380 G3 Server

Blue Screen of death


According to this link, the memory of Compaq Evo N610c can be upgradable to 1024 mb.\015\012\015\012http://h18000.www1.hp.com ... Compaq Evo N610C Notebook

Compaq proliant 5500 server P2 dual xeon processors. Will not power on. green lights on both powers supplies are on - green lights on Mother board and LCD on front are on but absolutely nothing happens when pushing power button


I am wondering if you had been doing some work to this when this problem started. Did you take the wires off for the power switch? I have noticed that sometimes if you pull the wires off of the motherboard and put them back on and you put the connect ... Compaq ProLiant 3000/5500 Redundant (306558B21) Fan Assembly

I HAVE A COMPAQ PROLIANT DL360 G1 SERVER. IAM GETTING A NON SYSTEM DISK ERROR. I NEED TO KNOW HOW TO FLIP THE SCSI DRIVERS.


... HP Compaq ProLiant DL360 G2 Server

What is it worth?


Honestly, it depends on the make (g1, g2, g3) and configuration (how many processors, amount of memory, how many disks, type of RAID card, redundant power and if it woks) I remember these machines were pretty bulletproof. Find out the config for ea ... HP Compaq ProLiant ML530 Server

Hp proliant ml350 g5 vga drivers for windows 2000 professional


Download the latest Proliant Support Pack from HP's web site. This will update the drivers for everything on the server at once.\015\012\015\012Just go to hp.com and click the link for "Support & Drivers" at the top, then click the r ... HP ProLiant ML350 G5 Server

Ecc I have got compaq n620c notebook, What kind of memory can I install, with ecc or without ecc?


The Compaq Evo N620c takes the PC2100 DDR SDRAM SODIMMs; maximum memory 2 GB. The ECC is a memory error control system which eliminates the posibility of RAM memory errors but is not required for operation; none ECC RAM should work just fine. Morover ... HP Compaq Evo n610c Notebook

02A2: BMC System Event Log(SEL) Full


In HP prolliant server sets, setup also logs system events. This error is due to that log. Enter setup, trace log and clear all events. ... HP Compaq ProLiant ML110 G4 Server

Compaq proliant 5500 server wont power up


In my experience when a server/computer does absolutely nothing when the power button is pressed it is a dead processor. That may not be the case in your situation. It could be as simple as a defective power switch. Is the switch a soft touch or does ... Compaq ProLiant 3000/5500 Redundant (306558B21) Fan Assembly

Hard drive controller


These can be fun and Hdd/IDE/SATA Controllers on Desktops are different than laptops.. Embedded controller chips as well as the Northbridge/Southbridge chips are integrated to everything else and its a nightmare to track down period. (Ive had to repl ... HP Pavilion dv1000 Notebook

Http/1.1 internal server error


\015\012Here is some great source to solve any kinds of laptop's problem.» Hp Laptop's Solution»  ... HP Pavilion dv9000z Notebook

HP proliant dl 360 g3 error code 1611 cpu fan failure


Remove all 6 fans, and then remove the fan rack itself. Then tighten\012the 2 pcb thumb-screws underneath. I believe this is sometimes the reason for false 'failed fan' reports. ... HP Compaq ProLiant DL360 G3 Server

Old Compaq Desktop Pro


The BIOS is unable to access the video system in order to write any error messages to the screen.This is usually caused by a problem with the video card, or the memory on the video card. It can also be a motherboard issue.If i ... Compaq PC Desktops

Just want some more memory


Getting additional memory\015\012The below commands will help allow your computer to load programs into memory more efficiently allowing you to have more memory for MS-DOS programs / ... Compaq Presario 5000 PC Desktop

Compaq Proliant server... sort of... died


What has happened the main board system battery is old and when you moved this server has lost setup first step is clean the system check the voltage without power applied you will find low voltage replace the battery rest you setup setting If this n ... HP Compaq ProLiant 6000 Server

Compaq Recovery CD Error


In my experience, weird errors like this are usually caused by bad RAM. I have to wonder why you are reinstalling in the first place, was your Windows installation corrupted and running funny?\015\012\015\012If you have access to another ... Compaq Presario 5000 PC Desktop

Server error HI I am Raviraj i am using hp proliant ml150 g3 server with windows 2000 server with sp 4. whenever i restart server i getting the error message like 02A2 BMC System Event Log (SEL)Full press f1 to continue kindly help regarding this


Clear System Event Log thru CMOS setup or the management software provided with server . The SEL is full that is the reason the error message ... HP ProLiant ML150 G3 Server

Installed more memory into Compaq V2000


The new ram you have installed, is it the same speed/type as what is already in the system?Take out the new ram and leave the old in. Try and boot. If all ok, swap out the old ram for the new and see if you can boot. If the system does not boot ... HP Compaq Presario V2000 Notebook