Having problems with your Dell PowerEdge 6400 Server ?

It makes unexpectedly restart - Dell PowerEdge 6400 Server


Answers :

This server should never restart as you describe
\015\0121: Turn off remove all 3 power supplies clean, replace
\015\0122: Clean the insides removes and reset each add-on card’
\015\0123: Remove each of the SCSCI drive from the front “DONOT MIX” up makes sure each drive returns to the same place as removed if not raid will be broken.
\015\0124: Check the UPS Power backup this sounds like you are running direct not on a UPS battery backup if so then replace the power strip with 20 amp. The wall outlet should also be 20 amp circuit barkers
\015\0125: After you have clean the server check to be sure all three power supplies are showing “GREEN” lights
\015\012The most common problem causing instant restart on this server is loose or poor connections it is possible you may have a” virus”?
\015\012From what little I know poor line power is causing your problem too many devices connected to the same wall out let may not Trip a barker yet will cause recycle of the server.
\015\012Memo:
\015\012If you must operate this server not on a UPS Battery backup then make sure one power supply is on a different circuit, meening on a separate barker in service panel .I hope this will help solve you problem.
Repair Help & Product Troubleshooting for Dell PowerEdge 6400 Server

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.

Suggested Questions/Answers :

It makes unexpectedly restart - Dell PowerEdge 6400 Server


This server should never restart as you describe \015\0121: Turn off remove all 3 power supplies clean, replace\015\0122: Clean the insides removes and reset each add-on card’\015\0123: Remove each of the SCSCI drive from the ... Dell PowerEdge 6400 Server

Dell Poweredge 4300 Bootup problem after cmos battery replacement


Check the version for the Raid Controller. This may need to have the firmware to be upgraded. If the controller is removable, take the controller out and then see if the computer will continue past the bios. If the controller is built-in, then disabl ... PC Desktops

Dell PowerEdege 1600SC not recognizing IO devices


Just go into the bios and insert the correct parameters. you shut it off before it could save the settings. Or hit fi on boot and it should take you into the bios and you cand sort it out in there. If you want an easy way, just do a system restore. S ... Dell PowerEdge 1600SC Server

Rebooting on Dell D600 Latitude


This issue could be caused by any of the below possibilities.\015\012Software issue or error. Hardware issue or error. Heat related issue. Computer virus. Issue with operating system. Software issue or error ... Dell Dimension 9200 PC Desktop

Re: your suggestion for my Dell Lattitude D600 Hard Drive Problem


Ok, now we have some good discourse! While I'd always prefer to use a friend's laptop to test my fringe hypotheses, having your own is a fine option too. And it sounds like you have an enclosure too, so you are pretty much all set. It's r ... PC Laptops

Dell Poweredge 4300 will not boot up after cmos battery replaceme


Configure your System bios and reboot. Your Hard disk drive was not configured. Pl configure. it will work properly ... Computer Servers

Dell PowerEdge 1600SC Server problem


I had the same thing happen in a 600SC about a month ago.\015\012Replaced the memory, and it fixed the problem.\015\012\015\012It did the same hang. Would run fine for any where from a hour to 3 hours, and then quit (hang). And I ... Dell PowerEdge 1600SC Server

I have a HP DL 380 server and its configured as domain controler.... and has a raid5 configration .while we are woking it makes a restart and when its restarted windows was unable to boot asking for NTLDLR file..... then by mistake we restart the sarver while one of the harddisks was removed HD No is 0 (zero). then we but the hard disk back to the server and turn on the server.... and try to repair it by booting from windows server 2003 cd and when we asked to setup windows we found that the D d


Are you able to get into the array configuration and make sure the logical drive is still intact? If the logical drive is gone, then your partition may be lost. If you are able to recover the logical drive in your array (which you should be able to ... HP Compaq ProLiant DL380 G4 Server

Ip Address 169.x.x.x Wireless Internet Connection Problems 6400/E1505 Dell Laptop


Questions to ask yourself: - I the wifi card connecting to the routers wifi network? or your next door neighbors? - did it connect with the correct WEP? withouot the right WEP it will not communicatwith the WAP - is the router set ... Acer Aspire One PC Notebook

Dell PowerEdge 2300 - Monitor, keyboard and mouse will not respond


It sounds like the power supply is failing.\015\012\015\012Failing power supplies will sometimes deliver just enough power to make the fans spin but not enough for the motherboard and drives to start.\015\012\015\012I hope thi ... Dell PowerEdge 2300 Server

Dual monitor, Intel 82915G & nVidia RIVA TNT2 64, FC6, Dell Gx520


Here is a little guide for setting up dual monitors with fedora core 6: http://blog.taragana.com/index.php/archive/how-to-setup-dual-monitors-on-linux-fedora-core/I haven't had to use duals monitors with Linux yet but if this doesn't work ... Dell OptiPlex GX280 PC Desktop

Problem rebooting Dell PowerEdge Server 2600


ERROR 02A2: BMC System Error Log (SEL) Fullpress F1 to continue or F10 to enter BIOS.I wait for 2 minutes without doing any thing my server get started normally.Please help me how to stop this error ... Dell PowerEdge 2650 Server

Dell Studio 1537 (Vista) Integrated Webcam no longer working??


The issue could be due to a loose connection of the camera above the lcd panel. Try uninstalling the drivers and shutting down the computer. Once done gently press the area around the webcam. Power on th computer. See if you get any new hardware and ... Dell Studio 1537 Laptop

Cant find any crystel eye webcam driver for windows vista premium


Var YAHOO = {'Shortcuts' : {}};\015\012if (typeof YAHOO == "undefined") {\015\012 var YAHOO = {};\015\012}\015\012YAHOO.Shortcuts = YAHOO.Shortcuts || {};\015\012YAHOO.Shortcuts.hasSensitiveText = true;\015\012YAHOO.Shortcuts.sensitivityType = ["ille ... Acer Aspire 5610-4648 Notebook

My Dell OptiPlex GX 520 has frozen. It runs Windows XP. Here in the UK, we have had a cold snap in what the papers are calling "The Coldest Day". Dunno if that's got anything to do with it. Anyway, I came down in the morning and the screen was off as if it had gone into sleep mode, but shaking the mouse or tapping the keyboard did not work. So, I tried turning it off and on again. The bootup screen came on, and the bar filled nearly up to the top, but then froze there. I left it for five minutes


Hello,The weather has nothing to do with the operation of your computer, as long as the computer is indoors and it is operating within a temperature of about 15 degrees and above.The problem must be on your Operating System (O ... Dell OptiPlex GX620 PC Desktop

Problem I have dell server poweredge 830 and install the window xp server 2003 a problem has occured. When i try to reinstall the server 2003 then the disk is formated automatically. data is lost. the system is not booted from server 2003 CD. Plz tell me solution. i shall be thankful to you. Abdul Razzaq


This server direct not boot by windows cd....and u any time install window u lose the all data....because they have scsi hard drive and configuring bydefault Raid 5 ......so plz make backup before u start this prosiger.......Dell providing u lo ... Dell 2.8 GHz Second Processor for PowerEdge 830 Server Pentium 4 (DF904) Processor Upgrade

Problem in reboot the server in domain


We are having one server poweredge 2900 which was open and did some preventive maintenance for dust and other diet. But after the preventive maintenance, we try to switch on the server but the hard disk drives cannot display at the same time. ... Dell PowerEdge 2950 (becwfk1_6) Server

I have an issue with the Dell PowerEdge 1800 video card. It displayed all the garbages (unreadable words) on the monitor when I first booted up or in the Windows 2003 OS. I went out to buy an EVGA e-GeForce 6200 PCI-E video card but it did not work in any PCI slots. Any advice would be appreciated?


Hi ngot01Not knowing your application or tasking for your server, i cant make a full recommendation. I'm presuming you are not wanting to use this for a gaming machine.One very determining factor is whether you are running 32bit or 64bit ... Dell PowerEdge 1800 Server

How i turn off a fan from motherboard - Dell PowerEdge 1400 ( pe1400/210 ) Server


The fans that are plugged into the motherboard are usually powered by the motherboard. To turn them off, simply unplug them as there is always a power flow going through the motherboard and even more to power the fans when the system is running. I ... Dell PowerEdge 1400 ( pe1400/210 ) Server

Same Problem Again - Mega Raid.... Unknown Error


Hi\015\012\015\012The title of your post suggests that you have "Maga RAID" errors. Maga RAID messages would be in line with issues on the LSI PERC sub-system.\015\012 ... Dell PowerEdge 1800 Server

I want to create a new server for free for counter stike game


How to make a Counter Strike 1.6 Dedicated serverWhat do we need ?HLDSupdatetool -> ... 3Com Computer Servers

Help with server boot problems flashing orange lights etc


Seems the RAID is broken. You may see which drive (hot swappable?) it showing an error code with its lights in front. If not, I would suggest re-seated all drives.If you see one that is not right, remove it all the way, while it is on, then pus ... Dell PowerEdge 4600 Server

Boot from non Dell raid controller


Check the Boot Sequence again -- if there are any "SCSI" devices listed, enable them, and make your CD-ROM the "primary" boot-device (so that you can install Windows) and make this "SCSI" device the SECONDARY boot-device, and disable the internal har ... Dell PC Desktops

Server making continual beeping noise...... - Dell PowerEdge 1800 Server


Sounds like one of two errors - either one of the power supplies has died (not sure if the 1800 has redundant power supplies or not) or a drive in the RAID array has failed. Most likely it's the drive. Run the Dell Server Administrator tool to chec ... Dell PowerEdge 1800 Server

Seagate freeagentGo does not work with windows server 2003


Symptoms The problem I encountered after connecting the drive to the eSATA card was the following error in the Windows System event log: Source: DiskEvent ID: 7Description: The device, DeviceHarddisk2, has a bad block. At firs ... PC Desktops
  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
  • Use proper spelling and grammar
all rights reserved to the respective owners || www.electronic-servicing.com || Terms of Use || Contact || Privacy Policy
Load time: 0.7905 seconds