Having problems with your Dell PowerEdge 1600SC Server ?

No Boot on 1600sc

\015 Hi,\015\012 \015\012I stripped down all the component parts from a Dell PowerEdge 1600sc Server to clean them before reinstating the server. On plugging in, the LED motherboard light (labelled D2, between the power connector and the front panel connector) lights green (continuous) but there is no other activity, no boot, no beeps, no post, no front panel lights, nothing.\015\012 \015\012I connected only the system HD (IDE), inserted memory (2x 512Mb) and single processor (single processor system only), fans, front panel connector, mouse, keyboard and monitor. All other hardware not connected until I was sure the system would boot.\015\012\015\012Note: the first 2x time on powering up, the fans came on and then the system powered down by itself after 5 seconds. But now nothing happens. Any suggestions?\015\012 \015\012Ric\015

Answers :

The easy answer is:\015\012\015\012Did you ensure the CPU fan connector is attached to the PROPER motherboard CPU fan power pins?\015\012\015\012The 2nd easy answer is:\015\012\015\012Are you sure your CPU is properly placed inside the socket? Could it be tilted slightly up on one side?\015\012\015\012The more complicated 3rd answer is:\015\012\015\012I've seen people use the spray can of AIR, which, believe it or not causes a moisture problem AND can overly cool a component. \015\012Although the motherboard looks fine, it won't boot or power on until the part(s) rewarm to room temperature or the moisture dissipates.\015\012\015\012This is how I solve this problem.\015\012\015\012I remove the motherboard or open it completely up to clean it with 80psi of compressed air. (remove all components)\015\012\015\012If it had previously been cleaned with a can of AIR, I let it sit for half an hour.\015\012\015\012When putting the parts back together (leave the HD, the CD, the floppy disconnected),\015\012(oh...ensure your front panel connectors are properly on the correct motherboard pins too.)\015\012\015\0121)take extra caution with both the video card and the memory chip slots!!\015\012Inspect the video card gold edge and video card slot for a few strands of carpet fiber or DUST bunnies wedged or attached to the card/slot (which causes the computer to not power ON)\015\012\015\0122) Inspect the memory sticks and memory slots in the same manner. (I had to see it with a magnifying glass, to see the problem)\015\012\015\012Once back together, if it boots, I'm done.\015\012\015\012If it didn't boot, I replace the power supply.\015\012\015\012If that didn't solve it, I reposition or change the RAM memory.\015\012\015\012Attention to detail is the key to success.\015\012\015\012ZT3000\015\012"Beta tester of "0"s and "1's"
Repair Help & Product Troubleshooting for Dell PowerEdge 1600SC Server

Tips for a great answer:

- Provide details, support with references or personal experience .
- If you need clarification, ask it in the comment box .
- It's 100% free, no registration required.

Suggested Questions/Answers :

No Boot on 1600sc


The easy answer is:\015\012\015\012Did you ensure the CPU fan connector is attached to the PROPER motherboard CPU fan power pins?\015\012\015\012The 2nd easy answer is:\015\012\015\012Are you sure your CPU is properly placed inside the socket? Could ... Dell PowerEdge 1600SC Server

Dell PowerEdge 1600SC Server problem


I had the same thing happen in a 600SC about a month ago.\015\012Replaced the memory, and it fixed the problem.\015\012\015\012It did the same hang. Would run fine for any where from a hour to 3 hours, and then quit (hang). And I ... Dell PowerEdge 1600SC Server

PowerEdge 1600SC long beep and hang


Check the Cmos battery. or levae pluged in over night and then check setup setting you battery went dead ... Dell PowerEdge 1600SC Server

Boot from CD is not recognizing the Windows 2003 Server CD


Hv u tried booting from other CDs .\015\012if u can boot from other CDs , then this 2003 CD is botched , change it. ... Dell PowerEdge 1600SC Server

Dell PowerEdege 1600SC not recognizing IO devices


Just go into the bios and insert the correct parameters. you shut it off before it could save the settings. Or hit fi on boot and it should take you into the bios and you cand sort it out in there. If you want an easy way, just do a system restore. S ... Dell PowerEdge 1600SC Server

No Video Signal on 1600sc


I also have this problem with my Dell Poweredge 1650, integrated Ati Rage XL doesn't work. But when I add PCI graphic card, I get the video from it. Could integrated video be somehow disabled? ... Dell PowerEdge 1600SC Server

Windows won't see all of my 4GB of RAM but BIOS does! Why?


Its simple you must have the system in OS install Mode, for some legacy OSs they can only install with 256 Max RAM.\015\012\015\012The setting is in the BIOS or setup. its easy to find and its called OS Install Mode ... Dell PowerEdge 1600SC Server

Can not access bois


My Dell 1600sc hung at bios screen. Progress bar qas about 10% . Problemed turned out to be a corrupted memory module - reved 3 out of 4 and tried to run worked and then process of elimination ... Dell PowerEdge 1600SC Server

I try to put xp home on the 1600sc


I am assuming that you mean it won't boot after you install by "It won't take". if so, you need to use the F6 key at the beginning (I mean the very beginning of booting from the CD). Keep pressing it until the question asking you to press F6 if neede ... Dell PowerEdge 1600SC Server

Bad Base code image Error during boot


Does it boot to the OS?You might have a corrupted registry and you might have to reinstall the software ... Dell PowerEdge 1600SC Server

Dell PE 1600SC invalid memory configuration detected


You may need to install memory in matching pairs. If the new memory is a single 1Gb module and you didn't already have a similar one they may not work together. Try removing the original module(s) and see if it makes a difference. ... Dell OptiPlex GX280 PC Desktop

Adding second CPU


Hi\015\012Did you receive a VRM with the the PRC upgrade kit? And have you installed it?\015\012The following items are/should be included in a microprocessor upgrade kit:• A microprocessor (PRC)& ... Dell PowerEdge 1600SC Server

I have lost the scsi drive on a dell 1600sc and would like to convert to sata. During boot up the sata controller is reconizing the 2 hard drives but, come but with "no primary drive found"


The best thing to do is reinstalling SCSI, SATA can only manage two disk per channel on this server, and the data transfer time is longer.If you set SATA, check jumper settings, that is probably reason why you get no primary drive.A ... Dell PowerEdge 1600SC Server

Hard disc Problem for server (powerEdge 1600SC)


Hi , I suppose its a issue with the RAM , Kindly check re-inserting the RAM on the server and try booting the system ... Dell PowerEdge 1600SC Server

Response to constant beeping on the dell 1600sc server


Please provide me a complete list of components on your server and I will be more than happy to help..Regards,Sai. ... Dell PowerEdge 1600SC Server

My compaq desktop computer wont start up it keeps saying NTLDR missing


Hi i have made lil resaerch for this problem so every user who suffurs from this problem can Fixt it on Fixya.com i wish this well helps everyone when u finish rate me plz cuz that was a day and half reasaerch took me a serious hard time but t(his i ... Compaq PC Desktops

My pc was doing this but now it's doing something different but simular


Try this: boot into the bios, set the boot order to cd rom first,hard drive 2nd and either one to 3rd. Hit F10 to save changes & exit. Put in your Windows cd. It should come up to a screen that says "Hit any key to boot to cd", do that. Set up sh ... E-Machines eMachines T3830 PC Desktop

Laptop wont boot from cd/dvd drive, hard drive is cleasn, no viru


\015\012Change the BIOS boot order so the CD or DVD drive is listed first. Some computers are \015\012already config ... Toshiba Satellite A105 Notebook

This Acer AST 160 I'm working on crashed...


Computer stops at verifying dmi pool data.\015\012Issue:\015\012Computer stops at verifying dmi pool data.\015\012Cause:\015\012This issue can be caused by any of the below reasons.\015\012\015\012Corrupt boot files o ... Acer Aspire T160 (AST160UA3400) PC Desktop

2 operating systems


The Boot Configuration Data (BCD) store contains boot configuration parameters and controls how the operating system is started in Microsoft®Windows Vista.\015\012Remove Windows Vista From Dual Boot System\015\012Windows Vista works slightl ... Acer Aspire 3680 Laptop

Blank screen after boot up


This issue may occur if one of the following conditions is true: \015\012Cause 1\015\012\015\012 loadTOCNode(3, 'cause');\015\012 \015\012This issue may occur if you have a CD, a DVD or a floppy disk in your CD, DVD, or floppy drive ... Dell Dimension 3000 PC Desktop

I can re boot boot my compaq persario V6000


Only a HDD with a properly installed OS, a valid boot sector and an active partition will 'Boot' Did\015\012it ever work? Are you sure the POWER is there. Are you sure the cables\015\012are on right and the HDD is identified in the BIOS o ... HP Compaq Presario V6000T PC Notebook

Acer 3690 I have a message ntldr is missing press any key....it wont start


Could be various causes just follow the information below and you should solve it.Good luckNTLDR is MissingPress any key to restart\015\012\011\011\011Boot: Couldn't find NTLDRPlease insert another disk\015\0 ... Acer Aspire 3690-2196 Notebook

Dell xps m1530 formatted hdd now it wont boot


You might find part of this general trouble shooting process might help? Especially the part of changing you Primary Boot drive so you can load Windows.\012\012Assuming you are Windows based and not knowing your specific OS? \012 Your p ... Dell XPS M1530 Laptop

Yea sorry, forgot that tid-bit of info. It,s the W3118 eMachine / Gateway FIC K8MC51G


This issue can be caused by any of the below reasons.-Corrupt boot files on the computer.-Settings for hard disk drive are not correct.-Floppy diskette or CD in computer causing issue.-Boot devices not set properl ... E-Machines eMachines Desktop PC
  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
  • Use proper spelling and grammar
all rights reserved to the respective owners || www.electronic-servicing.com || Terms of Use || Contact || Privacy Policy